Gold Member Since 2016
Audited Supplier
Suzhou Dongda Goldenpoint Technology Co., Ltd.

Central Control, Control, Public Bicycles manufacturer / supplier in China, offering Public Bicycles-Charge Type Central Control Cabinet, Public Bike-Vibrant Orange Steel Pipe Single Lock Double Column, Public Bike-Grass Green Double Shoulders and a Front Fork Bike and so on.

(/ )

Supplier Homepage Product Central Control Cabinet Public Bicycles-Charge Type Central Control Cabinet

Public Bicycles-Charge Type Central Control Cabinet

FOB Price: US $1,500-2,500 / Piece
Min. Order: 100 Pieces
Min. Order FOB Price
100 Pieces US $1,500-2,500/ Piece
Get Latest Price
Production Capacity: 60 Thousand Sets/Year
Transport Package: Wooden Binding
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Product Catalog
Central Control Cabinet
10 Products
Content
Product Image
Product Name
FOB Price
Port
Basic Info
  • Model NO.: JD-CONTROL-07
  • Structure: Combination
  • Signal: Discrete
  • Certification: CCC, ISO: 9001
  • Customized: Customized
  • Low Power Consumption: Less Than 11W
  • Fault Rates: 1/20,000
  • Trademark: golden point
  • Origin: China
  • Task: Program
  • Mathematical Model: Non-Linear
  • Function: Automatic Control
  • Condition: New
  • Material: Stainless Steel
  • Acceptable Temperature: -50ºC~+95ºC
  • Salt Spray Test: 96h
  • Specification: custom made
  • HS Code: 8537209000
Product Description
    The central control cabinet is composed of equipment cabinet, industrial display screen, metal anti-explosion keyboard, power manager, backup battery, communication module, central controller, etc. With the integral stoving varnish on the surface, the equipment cabinet is composed of stainless steel frame and is provided with cold-rolled sheet lining. With the interface for mains supply, solar energy and street lamp power supply, the central control cabinet can be connected to such power supply as street lamp power supply and solar energy under the unavailability of mains supply. By virtue of independent electric meter, the convenient electric charge settlement can be realized between the central control cabinet and various power supplies.
    The central controller is connected to the locker through CAN bus, and the central server is responsible for the uniform management of the leasee information and the bicycle lease business. Moreover, the central controller and the central server can communicate with each other through wired or wireless communication mode, and support VPN function, thus being effectively isolated with outer net. Meanwhile, such background task and adjustment as rate table modification, free period modification and locker software upgrading can be automatically realized for the locker through the central controller.

1.    Shell
1)    With cold-rolled sheet and outdoors sprayed plastic coating, the shell has excellent corrosion resistance and destructiveness resistance, and the paint can ensure no unnatural decoloration in outdoor environment for at least five years;
2)    Color and dimension can be customized according to user requirements, thus meeting integral VI design;
3)    With the design for the resistance to water, dust, salt, moisture and destruction, the system can adapt to the field operations in different climatic environments;

2.    Performance index
1)    Operating humidity: the system has passed the humidity detection in 98% RH environment;  
2)    The system can maximally load 384 lockers; 
3)    The system is provided with such communication modes as Ethernet and 3G for user choice; 
4)    Based on integral design and manufacturing, the control equipment with convenient installation and simple maintenance is composed of integral equipment cabinet, industrial embedded control mainframe, relevant network modules, etc.;
5)    The system is internally provided with anti-explosion keyboard and card reader, and the LCD display window has inquiry and display functions;
6)    Under normal mains supply, the accumulator can be charged through 220V mains supply and solar energy; in case of mains supply cutoff, the central control cabinet can be powered; the power supply can be monitored in a real-timer manner and the monitoring data can be uploaded to the background system;  
7)    As an option, the emergency power supply can ensure the normal operation of the locker under the unavailability of external power supply;
8)    With the interface for street lamp power supply, the system can be connected to the street lamp power supply, the solar energy, etc. under the unavailability of mains supply;
9)    Voltage and temperature control device is internally provided to transfer data to the control center in a real-time manner in order to make the control center know the power supply condition of the station in advance and meanwhile realize the high temperature alarm for fire prevention;
10)     The station controller has passed high/low temperature (-50ºC~+95ºC) detection;
11)     The station controller has the design for dust and water prevention, and the protection grade is IP56;
12)     The station controller has passed the safety test of the state-certificated professional organization;  
13)     The station controller has also passed the electromagnetic compatibility test of the state-certificated professional organization;
14)     The static power consumption of the station controller is as low as 11W;
15)     With such functions as high/low temperature alarm and low voltage alarm, the station controller can inspect the lockers of station in a real-time manner to realize authorization management, state monitoring and alarm functions for the lockers; 
16)     CAN2.0 bus technology is adopted for the station controller;
17)     The station controller has passed electrostatic discharge interference, surge (impact) immunity, power frequency magnetic field immunity, voltage fluctuation and flicker tests;
18)     The station controller has passed thunder strike test and insulation test (≥30,000 Ω);
19)     The station controller has passed 96h salt spray test;
20)     The station control can load 384 lockers;

3.    Basic function
1)    The system rate can be remotely updated by the background system to realize different charge standards; meanwhile, the system is provided with wired and wireless communication modes for convenient installation, and is compatible with C and G networks (C network refers to CDMA and G network refers to GSM);
2)    The system can automatically download according to the firmware programs provided by the background application management system and update the main boards of various bicycle positions;
3)    With notice information issuing function, the system is provided with light box advertising position, LED backlight and internal time controller;
4)    Members can independently inquire such information as bicycle borrowing-returning information, balance in the card, transaction record, near station position, borrowable quantity and returnable quantity; 
5)    The thunder protection facilities are provided from the power supply to the communication and the antenna;
6)    In case the bicycle cannot be returned at night due to the full occupancy of the parking space, the system can also provide the "overnight return" function for allowing the bicycle leasee to ride the bicycle home; 
7)    The member not taking the card can borrow the bicycle without a card through the station controller, and the bicycle borrowed thereby can be returned at various stations without any manual handling; 
8)    The automatic account opening function is available for the authorized IC card, without the need for field business handling;
9)    At least 20,000 offline transaction records and at least 10,000,000 backlist records can be stored;
10)     In case of system communication signal interruption, the bicycles can be also borrowed and returned, and the corresponding records can be automatically uploaded after communication recovery, without any influence on charging;
11)     The system can timely upload and download the data.
ItemsHardware parameters
technical standardØ  Financial IC card standard PBOC3.0 in the People's Bank of China
Ø  IC card standard in the Ministry of construction
CPU32 bit CPU, main frequency: 536MHz
RAM256MB DDR2 RAM
FLASH256MB NandFLASH
display screenIndustrial grade liquid crystal display
keyboard4 X 4 metal proof stainless steel key or capacitive sensing touch keyboard
communication interfaceWireless communication moduleBuilt in GPRS, CDMA1X and CDMA2000 and other wireless communication mode for the user to choose;
Ethernet interface10M/100M net mouth adaptive, support VPN function
CAN interfaceCAN 2 bus applications, at least with 64 car lock;
Card compatibilityNon contact card functionNon contact Mifare1 card support S50/S70 CPU card (Mifare PRO/X), SIMPASS chip card, card contact card etc.
PSAM card functionSupport 2 PSAM cards;
sensorWith temperature, voltage detection function
real-time clockSupport, the error is: + 2 seconds /24 hours
working voltageOutput voltage: DC 12V ~ 36V, input: AC ~ 220V
Power interfaceWith solar energy, street lamp power supply interface, in the case of no city electricity can be connected to street lamp, solar energy and other power supply;
emergency power supplyBuilt in emergency power supply, in case of no external power supply to ensure the normal operation of the car lock the car more than 48 hours;
lightning protectionLightning protection design, from the power to communication and antenna are increased lightning protection facilities.
soundThere is a high pitched voice, voice content can be flexible settings
Using environmentworking temperature:-50~+95ºC
Storage condition:-50ºC~+105ºC
Working humidity:4%-98%RH
levels of protectionIP56
reliabilityThe mean time to failure (MTBF) is not less than 50000 hours.
Public Bicycles-Charge Type Central Control CabinetPublic Bicycles-Charge Type Central Control Cabinet
Send your message to this supplier
Avatar
Miss Carol
*From:
To: Miss Carol
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now